WNR Lyse Reagent For Sysmex 5-Part Hematology Analyzers

WNR Lyse Reagent For Sysmex 5-Part Hematology Analyzers

WNR Lyse Reagent for Sysmex 5-Part Hematology Analyzers selectively lyses red blood cells while preserving white blood cells and nucleated red blood cells (NRBC) for optical differential analysis. The solution maintains target osmolality and pH balance to ensure accurate scattergram gating in the WNR channel.

Product Introduction

WNR Lyse Reagent for Sysmex 5-Part Hematology Analyzers selectively lyses red blood cells while preserving white blood cells and nucleated red blood cells (NRBC) for optical differential analysis. The solution maintains target osmolality and pH balance to ensure accurate scattergram gating in the WNR channel.

 

What Is Hematology Analyzer Lyse Reagent?

 

In 5-part differential blood analysis, lyse reagent breaks down mature erythrocyte membranes, releases bound hemoglobin, and conditions WBC and NRBC structures for fluorescence nucleic acid staining under semiconductor laser detection.

 

Application in Hematology Analysis

 

WBC & NRBC Differentiation: Lyses mature RBCs to isolate intact leukocytes and nucleated RBCs for optical quantification in the WNR scattergram.
Hemoglobin Determination: Converts released hemoglobin into a photometrically stable compound measured at 555 nm absorbance.

 

Compatible Analyzer Series

 

Sysmex XN Series

XN-550, XN-1000, XN-2000, XN-3000, XN-9000

Sysmex XN-L Series

XN-330, XN-350, XN-450, XN-550

Sysmex XS Series

XS-500i, XS-800i, XS-1000i

 

Product Specifications

 

Technical Parameter

Specification

Standard / Method

Physical Form

Clear, particle-free liquid

Visual inspection

pH (25°C)

4.80 ± 0.15

Potentiometric

Osmolality

180 ± 10 mOsm/kg

Freezing point depression

Conductivity (25°C)

12.5 ± 0.5 mS/cm

Conductivity meter

Background WBC

≤ 0.1 × 10⁹/L

Automated counter

Background RBC

≤ 0.02 × 10¹²/L

Automated counter

Background HGB

≤ 1.0 g/L

Spectrophotometry (555 nm)

Correlation Coefficient (R²)

≥ 0.995

Parallel clinical trial testing

Precision (CV%)

≤ 1.2%

10 consecutive runs

Unopened Shelf Life

24 months (2°C - 35°C)

Accelerated aging test

Open-Bottle Stability

60 days (15°C - 30°C)

Real-time stability tracking

 

Key Features

 

Scattergram Alignment: Osmolality and pH tolerance controlled within ± 1% to match baseline gating limits and prevent cluster overlap.

Sub-Micron Filtration: Processed through 0.1 μm inline membranes to eliminate insoluble micro-particles and prevent fluidic tube clogging.

Buffer Capacity: Organic acid buffering system maintains target pH during extended operational runs at elevated ambient temperatures.

Optical Clarity: Absorbance baseline verified per batch to prevent photometric offset in hemoglobin detection.

 

Package & Storage

 

Available Sizes: 4 L rigid HDPE bottle, 5 L flexible cubitainer, custom bulk packaging.

Storage Conditions: 2°C - 35°C. Keep container closed away from direct light and heat sources.

Handling: Protect from freezing during transit. Allow temperature equilibration to 15°C - 30°C before installation.

 

Manufacturing & Supply Quality

 

Water System: Deionized supply with resistivity maintained at ≥ 18.2 MΩ·cm and total organic carbon (TOC) < 10 ppb.

Cleanroom Filling: Formulated and bottled in ISO Class 8 (Class 100,000) controlled cleanroom environments.

Quality Management: Production facilities operates under ISO 13485 certified quality systems for medical devices.

Batch Release Control: Every lot undergoes physical parameter verification, background testing, and parallel analyzer validation before dispatch.

 

Related Hematology Reagents

 

  • Cell Diluent for 5-Part Hematology Analyzers
  • FNR Lyse Reagent
  • SLS Hemoglobin Lyse Reagent
  • Enzymatic Probe Cleaner

FAQ

 

Q: How does this WNR lyse reagent maintain cluster separation on Sysmex 5-part analyzers?

A: The formulation enforces strict pH (4.80 ± 0.15) and osmolality (180 ± 10 mOsm/kg) control, ensuring stable RBC membrane dissolution and consistent laser light scattering in the WNR channel.

Q: What prevents micro-particle contamination from causing fluidic tube blockage?

A: During production, all liquid passes through multi-stage 0.1 μm filtration systems. Batch release requires background counts to remain strictly below 0.1 × 10⁹/L for WBC and 0.02 × 10¹²/L for RBC.

Q: Are adjustments or system recalibrations necessary when replacing reagents?

A: No fluidic recalibration or software setting adjustments are required. Bottle cap assemblies and tube connectors fit directly into standard analyzer intake ports.

Q: What evidence supports batch-to-batch consistency for large procurement orders?

A: Each production lot is manufactured under ISO 13485 protocols, using automated inline monitoring for conductivity, refractive index, and density. A Certificate of Analysis (COA) detailing physical and operational test results accompanies every shipment.

Q: What OEM or bulk packaging choices are available for distributors?

A: Standard supply formats include 4 L HDPE bottles and 5 L cubitainers. Private labeling, custom outer carton branding, and bulk liquid drum shipments are provided upon request.

Hot Tags: wnr lyse reagent for sysmex 5-part hematology analyzers, China wnr lyse reagent for sysmex 5-part hematology analyzers manufacturers, suppliers, Hematology Analyzer Sample Probe Cleaning Solution

Send Inquiry

whatsapp

Phone

E-mail

Inquiry

Bag