EZ Cleaner For Mindray 3-Part Hematology Analyzers

EZ Cleaner For Mindray 3-Part Hematology Analyzers

EZ Cleaner provides active deproteinization and liquid circuit maintenance for 3-part differential cell counters, dissolving residual cellular protein deposits to ensure consistent volumetric sampling and stable background parameters.

Product Introduction

EZ Cleaner provides active deproteinization and liquid circuit maintenance for 3-part differential cell counters, dissolving residual cellular protein deposits to ensure consistent volumetric sampling and stable background parameters.

 

What Is a Hematology Analyzer Cleaner?

 

A hematology analyzer cleaner is a dedicated maintenance reagent formulated with active surfactants and proteolytic agents. It systematically removes cellular debris, fibrin residue, and accumulated protein films from liquid channels, mixing cups, and sampling components.

 

Role in Analyzer Maintenance

 

Continuous application of cleaning solution prevents aperture occlusion, controls carryover contamination, and stabilizes baseline background metrics. Proper maintenance maintains fluidic pressure consistency and prevents operational failure in clinical test settings.

 

Cleaning Application

 

Probe Cleaning
Cleans internal and external surfaces of sampling needles to eliminate carryover contamination and preserve volumetric accuracy.
Fluidics Cleaning
Dissolves residual cell debris and lipid films within hydraulic valves and fluidic channels to keep operational pressure stable.
System Cleaning
Decontaminates mixing chambers, counting baths, and waste pathways during automated maintenance cycles.
Routine Maintenance
Executes daily wash operations to eliminate background noise and prevent aperture blockage.

 

Compatible Analyzer Series

 

  • Automated 3-Part Differential Cell Counters
  • Benchtop Hematology Testing Systems
  • Compact Clinical Laboratory Reagents Platforms

 

Cleaning Procedure / Recommended Use

 

Daily Shutdown Maintenance
Aspirate the required volume of cleaner through the sampling probe during the instrument automated shutdown protocol to prevent residue drying overnight.
Weekly Deep Maintenance
Run the dedicated wash cycle through the software interface, soaking fluidic lines and counting apertures for the complete cycle duration.
Aperture Maintenance Protocol
If background counts exceed acceptable ranges, execute the maintenance function to soak the counting aperture directly before flushing with diluent.

 

Product Specifications

 

Item

Technical Parameter

Product Name

EZ Cleaner

Formulation

Enzymatic Alkaline Solution

Appearance

Clear liquid

pH Range

9.0 – 11.0

Density

1.01 – 1.03 g/cm³

Background WBC

≤ 0.2 × 10⁹/L

Background RBC

≤ 0.02 × 10¹²/L

Background HGB

≤ 1 g/L

Background PLT

≤ 10 × 10⁹/L

Certifications

ISO 13485, CE

 

Package / Storage

 

Packaging Parameter

Specification

Volume Options

100 mL, 500 mL, 1 L, 5 L

Container Material

HDPE bottle

Seal Type

Induction-sealed cap

Storage Temperature

2°C – 35°C

Shelf Life

24 Months

Open-Vial Stability

60 Days

 

Related Reagents

 

  • Diluent for 3-Part Hematology Analyzers
  • Lyse Reagent for 3-Part Hematology Analyzers
  • Concentrated Probe Cleaner
  • Enzymatic Cleanser

 

fAQ

 

Q: Is EZ Cleaner directly compatible with standard 3-part hematology analyzer fluidic paths?

A: Container threading, tubing connections, liquid viscosity, and physical properties match automated system requirements, allowing direct installation without modifying fluidic settings.

Q: What is the required storage temperature for EZ Cleaner?

A: Store unopened containers between 2°C and 35°C in a dry environment protected from direct sunlight.

Q: Does EZ Cleaner affect internal plastic or rubber hydraulic components?

A: The formulation utilizes non-corrosive surfactants safe for clinical-grade silicone, PVC, PTFE, and rubber tubing used in analyzer fluidic networks.

Q: How does EZ Cleaner stabilize background measurements?

A: The solution breaks down protein deposits in the counting aperture, keeping the micro-orifice clear for accurate electrical impedance readings.

Q: What is the open-vial stability duration after opening?

A: The solution maintains full operational stability for 60 days when kept tightly capped at room temperature.

Hot Tags: ez cleaner for mindray 3-part hematology analyzers, China ez cleaner for mindray 3-part hematology analyzers manufacturers, suppliers, Hematology Calibrators