Probe Cleaner For Mindray Hematology Analyzers

Probe Cleaner For Mindray Hematology Analyzers

Probe Cleaner for Mindray Hematology Analyzers is an enzymatic fluidic maintenance formula engineered to dissolve co-agulated blood proteins, cell debris, and lipid deposits from sample probes, counting apertures, and internal tubing networks. Formulated with targeted proteolytic enzymes and non-ionic surfactants, the solution stabilizes background count readings, prevents aperture blockages, and preserves fluidic valve integrity.

Product Introduction

Probe Cleaner for Mindray Hematology Analyzers is an enzymatic fluidic maintenance formula engineered to dissolve co-agulated blood proteins, cell debris, and lipid deposits from sample probes, counting apertures, and internal tubing networks. Formulated with targeted proteolytic enzymes and non-ionic surfactants, the solution stabilizes background count readings, prevents aperture blockages, and preserves fluidic valve integrity.

 

Function and Mechanism

 

Automated blood cell count cycles deposit microscopic protein layers along micro-apertures and optical flow cells over time. Left untreated, these organic residues cause baseline count drift and electrical impedance errors. Probe Cleaner Solution acts directly on fibrin and cell membrane residue, converting insoluble protein matrixes into water-soluble compounds that are completely rinsed out during automated cleaning cycles.

 

Fluidic Maintenance Scope

 

Sample Needle Deproteinization: Cleans inner and outer sample probe surfaces to eliminate sample carryover and dried blood crusts.

Aperture Clearing: Removes organic film from micro-apertures, preserving constant electrical resistance for cell sizing accuracy.

Flow Path Hygiene: Prevents lipid accumulation inside solenoid valves, rubber manifolds, and peristaltic pump tubing.

System Flushing: Clears reaction baths and mixing chambers during automated shutdown and standby procedures.

 

Instrument System Compatibility

 

Formulated for high-throughput 5-part and 3-part differential automated hematology analyzers, as well as integrated automated blood analysis lines requiring dedicated enzymatic cleaning reagents.

 

Maintenance Procedure Guidelines

 

Routine Daily Shutdown: Initiate the standard system shutdown sequence via software. The fluidic system automatically draws the defined reagent volume into the internal paths.

Weekly Soak Cycle: For scheduled maintenance, introduce the solution into reaction chambers and allow a 10 to 15-minute soak time to digest stubborn protein coats.

Rinse Phase: Execute the system rinse command post-soak. The analyzer flushes all residual cleaner using isotonic diluent until background values meet operating parameters.

Exterior Wipe: Clean external sample needle tips manually using a lint-free wipe moistened with cleaning solution to prevent salt buildup.

 

Technical Specifications

 

Parameter

Performance Indicator

Physical Form

Clear, transparent, particle-free liquid

pH Value (25°C)

10.5 – 12.5

Density (20°C)

1.02 – 1.05 g/cm³

Active Components

Proteolytic enzymes, non-ionic surfactants, stabilizing matrix

Solubility

Complete miscibility in aqueous fluids

Material Compatibility

Non-corrosive to stainless steel, PTFE, silicone, and rubidium seals

Background Count Target

WBC ≤ 0.2 × 10⁹/L, RBC ≤ 0.02 × 10¹²/L, HGB ≤ 1 g/L, PLT ≤ 10 × 10⁹/L

Unopened Shelf Life

24 Months

Open-Vial Stability

60 Days

 

Packaging and Storage Specifications

 

Parameter

Standard Requirement

Available Volumes

50 mL, 100 mL, 500 mL, 1 L, 2 L, 5 L

Container Material

High-Density Polyethylene bottle with inner sealing cap

Storage Temperature

2°C – 30°C

Transport Requirements

Sealed upright storage, protected from light and freezing

 

Complementary Reagent Portfolio

 

Hematology Diluent: Isotonic buffer solution for cellular suspension and volumetric counting.

Hemolysis Reagent: Cyanide-free lysing agent for hemoglobin determination and leukocyte differentiation.

Concentrated Wash Solution: High-strength solution for periodic deep system descaling.

Enzymatic Maintenance Fluid: Targeted wash formulation for micro-fluidic manifolds and valves.

 

Technical Questions and Answers

 

Q: How does this cleaning solution restore baseline background counts?

A: Background count elevation occurs when residual protein fragments accumulate inside counting baths and micro-apertures. The active proteolytic enzymes break down organic matrices into small soluble molecules, allowing full removal during diluent flush cycles and returning background readings to baseline specification limits.

Q: What prevents this reagent from damaging internal rubber or plastic valves?

A: The formula uses material-neutral surfactant systems tested against medical-grade fluoroelastomers, silicone, stainless steel, and PTFE. It removes organic build-up without causing hardening, cracking, or swelling of internal seals.

Q: Can this solution resolve complete aperture clogs?

A: Yes. For complete aperture blockages, execute a targeted soak command through system diagnostics. Allowing the solution to remain in direct contact with the micro-aperture for 10 to 15 minutes digests the coagulated blood clot structure.

Q: How should open-vial stability be managed?

A: The solution maintains enzymatic activity for 60 days post-opening when kept tightly capped within the 2°C to 30°C temperature range. Closing the cap tightly after each routine cycle prevents atmospheric oxidation and airborne contamination.

Q: What quality standards govern product batch release?

A: Manufacturing operates under ISO 13485 quality management conditions. Each production batch undergoes analytical testing for pH, density, optical clarity, and background count verification prior to final lot packaging and shipment release.

Hot Tags: probe cleaner for mindray hematology analyzers, China probe cleaner for mindray hematology analyzers manufacturers, suppliers, Hematology Calibrators