Diluent for 3-Part Hematology Analyzers is an isotonic electrolyte solution formulated for precise blood cell suspension, volumetric sizing, and baseline counting on automated 3-part differential systems. Manufactured under ISO 13485 quality standards, the reagent maintains stable osmolality and neutral pH to preserve cell morphology throughout testing cycles.
What Is Hematology Analyzer Diluent?
Hematology analyzer diluent is an isotonic aqueous solution designed to dilute whole blood specimens to measurable concentration levels. It creates a stable conductive environment required for electrical impedance counting while preserving erythrocyte and platelet structures prior to analysis.
Application in Hematology Analysis
Cell Suspension and Sizing: Dilutes whole blood to facilitate accurate counting and volume sizing of erythrocytes and platelets using electrical impedance methodology.
Fluidic Flushing: Cleans sensing micro-apertures and liquid channels between analytical runs to eliminate sample carryover.
Baseline Measurement: Functions as a blank reference fluid to establish baseline electrical conductivity and ensure zero background interference.
Compatible Analyzer Series
3-Part Differential Systems: Fully verified for multi-channel 3-part differential automated hematology platforms using 20 µL sampling systems.
Sampling Modules: Suitable for both open-vial and closed-tube fluidic pathways.
Product Specifications
|
Parameter |
Specification Standard |
|
Appearance |
Clear, colorless liquid |
|
pH (25°C) |
7.0 – 7.6 |
|
Osmolality |
310 – 350 mOsm/kg |
|
Conductivity |
17.0 – 20.0 mS/cm |
|
WBC Background |
≤ 0.2 × 10⁹ / L |
|
RBC Background |
≤ 0.02 × 10¹² / L |
|
HGB Background |
≤ 1 g/L |
|
PLT Background |
≤ 10 × 10⁹ / L |
|
Shelf Life |
24 months |
|
Open Stability |
60 days |
Key Features
Osmotic Stability: Controls osmotic pressure to prevent cell shrinkage or swelling during impedance measurement.
Low Background Noise: Processed through sub-micron liquid filtration to keep particle counts below standard diagnostic thresholds.
Fluidic Protection: Chemical formulation prevents crystallization and micro-aperture blockages in liquid pathways.
Lot Consistency: Synthesized in automated bulk reactors to deliver steady calibration performance across batches.
Package & Storage
Volume Options: Available in 20 L cubitainers with secure sealing caps; customized sizes available upon request.
Storage Range: Store between 2°C and 35°C away from direct sunlight and freezing conditions.
Container Material: High-density polyethylene designed for maritime transport stability and stress-crack resistance.
Manufacturing & Supply
Production takes place in certified ISO 9001 and ISO 13485 facilities equipped with purified water processing systems yielding conductivity under 1.0 µS/cm, combined with inline 0.1 µm filtration. Each batch undergoes spectrophotometric testing, pH verification, osmolality validation, and baseline instrument checks before release. Certificates of Analysis and Safety Data Sheets accompany every shipment.
Related Hematology Reagents
Lyse Reagent for 3-Part Hematology Analyzers: Lytic agent for hemoglobin determination and leukocyte differential counts.
Probe Cleaner: Enzymatic solution designed for routine cleaning of sampling probes and internal lines.
Concentrated Rinse Solution: Surface-active fluid for periodic protein removal from liquid channels.
FAQ
Q: How does this solution prevent aperture blockage during continuous operation?
A: Multi-pass 0.1 µm filtration removes microscopic particulate matter during filling. Anti-protein deposition components within the formulation minimize residue build-up in fluidic pathways.
Q: What is the functional stability period after opening the container?
A: The solution retains stable performance characteristics for 60 days post-opening when connected via sealed fluidic connectors and maintained between 2°C and 35°C.
Q: Is system recalibration required when introducing a new reagent lot?
A: Running standard baseline checks and quality controls is recommended upon lot transition. Because key physical parameters match standard reagent criteria, full calibration is typically unneeded unless indicated by control material values.
Q: Does temperature variation during ocean freight affect product stability?
A: The formulation maintains integrity across transport temperatures ranging from 2°C to 35°C, provided the liquid remains unfrozen during transit.
Q: What documentation accompanies the shipment for local regulatory compliance?
A: Every batch includes a Certificate of Analysis. Safety Data Sheets, ISO documentation, and technical registration dossiers are available upon request.
Hot Tags: diluent for mindray 3-part hematology analyzers, China diluent for mindray 3-part hematology analyzers manufacturers, suppliers, Hematology Calibrator Set










