Platelet Dye for Sysmex Hematology Analyzers utilizes high-purity fluorochrome chemistry to deliver precise cell staining for optical detection channels. The formulation permeates cellular membranes inside the reaction chamber, binding specifically to intracellular nucleic acids under semiconductor laser excitation. This reaction minimizes background signal interference while maintaining stable optical scattergrams across high-throughput clinical testing.
What Are Hematology Stain / Dye Reagents?
Automated hematology dye reagents are fluorochrome solutions engineered for 5-part and 6-part differential blood analyzers operating with semiconductor laser flow cytometry. Unlike manual microscopic blood smear stains, these liquid chemical dye formulations permeate cellular membranes inside the instrument reaction chamber to bind directly with intracellular RNA and DNA. Upon laser excitation, the resulting fluorescent light emission measures cellular structure, volume, and nucleic acid content.
Role in Cell Classification / Detection
In laser flow cytometry, fluorescent dye reagents provide contrast to resolve overlapping cell populations in blood samples:
Nucleic Acid Binding: Permeates leukocyte and reticulocyte membranes to bind intracellular RNA and DNA structures.
Fluorescence Intensity Differentiation: Distinguishes mature erythrocytes from reticulocytes and mature platelets from immature platelet fractions based on nucleic acid density.
Cell Debris Separation: Suppresses non-specific binding, preventing micro-clots, fragmented red blood cells, and giant platelets from skewing counts.
Atypical Cell Flagging: Generates distinct side-fluorescence signals to isolate abnormal lymphocytes, blast cells, and nucleated red blood cells.
Detection Channel
Automated optical channels require specific fluorochrome dye formulations to tag cellular targets:
PLT Channel: Stains intracellular RNA in platelets to differentiate them from erythrocyte debris and microcytes via optical fluorescence, eliminating volume-based counting errors.
WNR Channel: Selectively lyses red blood cells while preserving leukocyte nuclei and nucleated red blood cells for simultaneous count and classification.
WDF Channel: Stains cytoplasmic and nuclear RNA/DNA of neutrophils, lymphocytes, monocytes, and eosinophils to resolve 5-part leukocyte differentials.
WPC Channel: Differentiates normal white blood cells from immature precursor cells based on lipid membrane permeability and nuclear density variations.
RET Channel: Tags residual ribosomal RNA in immature erythrocytes to quantify reticulocyte percentages and immature reticulocyte fractions.
Compatible Analyzer Series
|
XN Series |
XN-550, XN-1000, XN-2000, XN-3000, XN-9000 |
|
XN-L Series |
XN-330, XN-350, XN-450, XN-550 |
|
XS Series |
XS-500i, XS-800i, XS-1000i |
|
XT Series |
XT-1800i, XT-2000i, XT-4000i |
|
XE Series |
XE-2100, XE-5000 |
Product Specifications
|
Specification Item |
Technical Parameter |
|
Product Line Code |
STAC-DYE Series |
|
Model Variants |
STAC-DYE-SYSWNR / STAC-DYE-SYSWDF / STAC-DYE-SYSWPC / STAC-DYE-SYSRET / STAC-DYE-SYSPLT |
|
Physical State |
Clear liquid solution |
|
Target Optical Channel |
PLT, WNR, WDF, WPC, RET |
|
Excitation Wavelength |
633 nm – 635 nm (Red semiconductor laser) |
|
Operating pH |
6.80 – 7.40 at 25°C |
|
Filtration Rating |
0.1 µm absolute liquid filtration |
|
Background Signal Interference |
< 0.1% baseline fluorescence |
|
Background Count Range |
PLT ≤ 10 × 10^9/L, WBC ≤ 0.10 × 10^9/L, RBC ≤ 0.02 × 10^12/L |
|
Unopened Shelf Life |
18 months (stored at 2°C – 35°C) |
|
On-Board Open Stability |
60 days |
|
Batch-to-Batch Variance |
CV < 2.0% |
Application & Reagent Function
Optical Platelet Counting (PLT Channel)
Fluorochrome dye binds intracellular RNA, isolating platelets from small red cells or cell fragments in complex blood samples.
5-Part Leukocyte Differential (WDF Channel)
Diffuses into white blood cells to bind nucleic acids, producing fluorescent signal variations that separate lymphocytes, monocytes, neutrophils, and eosinophils.
Nucleated Red Blood Cell Isolation (WNR Channel)
Targets nuclear material in nucleated red blood cells and white blood cells simultaneously, preventing nucleated red blood cells from inflating total white cell counts.
Immature Cell & Blast Screening (WPC Channel)
Permeates lipid membranes of immature blasts and atypical cells to generate distinct scattergram clusters during oncology screening.
Reticulocyte Analysis (RET Channel)
Stains residual RNA in young red blood cells, enabling measurement of bone marrow erythropoietic activity.
Package / Storage
|
Component |
Packaging & Storage Parameter |
|
Fill Volume |
12 mL cartridge / 42 mL bottle |
|
Primary Container |
Light-shielded fluorinated high-density polymer bottle with tamper-evident seal |
|
Secondary Packaging |
Corrugated outer carton with shock-absorbing foam inserts |
|
Storage Temperature |
2°C to 35°C (Shield from direct sunlight; do not freeze) |
|
Transportation Limit |
Continuous exposure above 40°C must not exceed 72 hours |
Related Hematology Reagents
Automated Lyse Reagents: Isotonic lysing solutions formulated for rapid hemoglobin conversion and erythrocyte dissolution.
Diluent Solutions: High-purity buffered electrolyte solutions that maintain cell volume and stable conductivity.
Sheath Fluid: Low-background laminar flow solutions for hydrodynamically focusing cells in optical flow cells.
Enzymatic Cleaning Solutions: Proteolytic cleaning solutions formulated to remove protein deposits from fluidic pathways.
FAQ
Q: What is the shelf life and open-vial stability of these dye reagents?
A: Unopened bottles maintain an 18-month shelf life when stored between 2°C and 35°C. Once installed on the analyzer, open-vial stability remains verified for 60 days under normal operating conditions.
Q: How does optical fluorescent platelet dye differ from standard impedance counting?
A: Impedance counting measures cell volume and can register microcytic red blood cells or cell debris as platelets. Fluorescent dye binds nucleic acids inside platelets, isolating them optically on the scattergram for accurate counts even in severely thrombocytopenic samples.
Q: Are adjustments required when introducing these dye reagents?
A: The chemical formulations match the osmotic pressure, pH, conductivity, and fluorescence excitation profiles required for standard optical channels. Routine quality control runs confirm baseline performance without software or fluidic recalibration.
Q: How are light and temperature sensitivities managed during transit?
A: Fluorescent dyes decompose under direct light and freezing conditions. Reagents are packaged in light-opaque polymer containers and shipped in insulated outer packaging to maintain stable thermal conditions between 2°C and 35°C.
Q: How do these reagents prevent background optical interference in flow cells?
A: Formulations undergo multi-stage 0.1 µm absolute filtration and utilize ultra-pure fluorophores. This prevents unbound dye aggregation and keeps background fluorescence noise below 0.1%.
Hot Tags: platelet dye for sysmex hematology analyzers, China platelet dye for sysmex hematology analyzers manufacturers, suppliers