Reticulocyte Dye for Sysmex Hematology Analyzers provides targeted fluorescent nucleic acid staining for semiconductor laser flow cytometry platforms. The liquid reagent enters nucleated blood cells, reticulocytes, and platelets to bind selectively with intracellular RNA and DNA, generating specific side fluorescence and light scatter signals across designated detection channels. Formulated for direct integration with automated fluidic systems, the solution maintains stable fluorescence intensity, low background noise, and reproducible lot-to-lot performance in clinical laboratory settings.
What Are Hematology Stain / Dye Reagents?
Automated hematology dye reagents are liquid fluorescent markers engineered for flow-cytometry-based cell analysis platforms. Unlike traditional manual blood smear stains used in light microscopy, these liquid dyes enter target cells through controlled membrane permeabilization to label intracellular nucleic acids. Under semiconductor laser excitation inside the optical flow cell, the labeled cellular structures emit side fluorescence and light scatter signals, allowing system optics to generate precise two-dimensional scattergrams and cell cluster distributions.
Role in Cell Classification / Detection
In optical hematology analysis, fluorescent dyes enable differential cell discrimination by quantifying intracellular nucleic acid density:
White Blood Cell Differential: Separates lymphocytes, monocytes, neutrophils, eosinophils, and basophils based on RNA/DNA ratios and cytoplasmic structure.
Atypical & Immature Cell Identification: Identifies blast cells and immature granulocytes via elevated fluorescence emission intensity.
Reticulocyte Enumeration: Measures residual ribosomal RNA in young red blood cells to assess bone marrow erythropoietic activity.
Optical Platelet Counting: Resolves giant platelets and differentiates red blood cell fragments from platelets using target nucleic acid fluorescence gating.
Detection Channel
The fluorescent dye operates across specific automated optical channels:
WNR Channel: Counts white blood cells and isolates nucleated red blood cells through differential nucleic acid staining.
WDF Channel: Differentiates mature leukocyte subpopulations and detects immature granulocytes using side fluorescence and side scatter parameters.
WPC Channel: Screens for progenitor cells and abnormal lymphocytes based on nuclear density and differential membrane permeability.
RET Channel: Measures reticulocyte fractions and optical red blood cell parameters through RNA fluorescence intensity.
PLT Channel: Labels platelet nucleic acids to eliminate microcytic red blood cell interference during optical counting.
Compatible Analyzer Series
Formulated for direct operational alignment with automated hematology platforms utilizing semiconductor laser flow cytometry:
XN Series: XN-1000, XN-2000, XN-3000, XN-9000, XN-L Series (XN-350, XN-450, XN-550)
XS Series: XS-500i, XS-800i, XS-1000i
XT Series: XT-1800i, XT-2000i, XT-4000i
XE Series: XE-2100, XE-5000
Product Specifications
|
Parameter |
Technical Specification |
|
Physical Form |
Liquid solution, clear to light yellow |
|
Excitation Wavelength |
633 nm / 635 nm |
|
Emission Wavelength |
650 nm – 670 nm |
|
Target Binding |
Ribonucleic Acid (RNA) & Deoxyribonucleic Acid (DNA) |
|
Lot-to-Lot CV |
< 2.0% (SFL channel) |
|
Particulate Filtration |
0.2 µm absolute membrane filtered |
|
pH Range |
7.20 – 7.50 at 25°C |
|
Osmolality |
280 – 320 mOsm/kg |
|
Quality Standard |
ISO 13485 / CE IVD compliant |
Application & Reagent Function
WNR Channel Staining (STAC-DYE-SYSWNR): Permeabilizes cell membranes to allow rapid nuclear dye entry, separating intact NRBC nuclei from white blood cells for precise NRBC % and WBC count generation.
WDF Channel Staining (STAC-DYE-SYSWDF): Stains intracellular nucleic acids of leukocytes to generate distinct scattergram clusters for neutrophils, lymphocytes, monocytes, and eosinophils.
WPC Channel Staining (STAC-DYE-SYSWPC): Selectively stains blast cells and abnormal lymphocytes based on lipid composition and nuclear density for secondary cell flagging.
RET Channel Staining (STAC-DYE-SYSRET): Binds to residual RNA in immature red blood cells, enabling calculation of total reticulocyte percentage, absolute count, and immature reticulocyte fraction.
PLT Channel Staining (STAC-DYE-SYSPLT): Labels platelet nucleic acids to prevent microcytic red blood cell interference during low-count optical platelet measurements.
Package / Storage
Packaging Configurations:
- Cartridge cassettes: 2 × 12 mL
- Bottled solution: 1 × 50 mL, 1 × 100 mL, 1 × 500 mL
Storage Temperature: 2°C to 30°C (Protect from direct light and freezing)
Unopened Shelf Life: 18 months
On-Board Stability: 60 days in ambient laboratory conditions
Related Hematology Reagents
Hematology Diluent Solutions: Isotonic buffer solutions maintaining cell volume integrity and controlling fluid conductivity during physical measurements.
Lyse Reagents for Leukocyte Differential: Active solutions that selectively lyse red blood cells to prepare white blood cells for optical analysis.
Analyzer Cleaning Solutions: Enzymatic washing fluids designed to clear protein buildup and dye residue from internal fluidic lines and optical flow cells.
Concentrated Sheath Fluids: Hydrodynamic fluids formulated to center sample streams inside optical detection chambers.
FAQ
Q: How does this dye prevent signal overlap between reticulocytes and mature red blood cells?
A: The dye targets RNA strands present in reticulocytes. Mature red blood cells contain no functional RNA or DNA, emitting no background fluorescence under laser excitation, which creates distinct baseline separation on optical scattergrams.
Q: What is the open-vial stability of the reagent once loaded into the instrument?
A: The liquid formulation remains stable on-board for up to 60 days between 2°C and 30°C. Stabilization agents prevent concentration shifts and maintain constant fluorescence emission throughout the usage cycle.
Q: Are hardware or software adjustments required when introducing this dye reagent?
A: The reagent matches standard physical-chemical parameters, excitation response curves, and fluidic viscosity, allowing direct operation under established system calibration protocols.
Q: How does the liquid formulation protect optical flow cells from particle accumulation?
A: Solutions are processed through 0.2 µm absolute membrane filters during final packaging. The non-aggregating dye structure prevents micro-particulate formation and residue buildup within fluidic lines and nozzles.
Q: What documentation accompanies batch shipments for quality verification?
A: Deliveries include a Certificate of Analysis (CoA), Safety Data Sheet (SDS), lot testing records, and ISO 13485 compliance documentation.
Hot Tags: reticulocyte dye for sysmex hematology analyzers, China reticulocyte dye for sysmex hematology analyzers manufacturers, suppliers